Stainless Steel Rectangular Formaldehyde Sterilizer
₹20,00,000.00
Specification
- shape
- Rectangular
- material
- Stainless Steel
- application
- Hospital
- availability
- In Stock
- chamber volume
- 600
- pressure range
- 1- 30 PSI
- insulation wall
- Triple Wall
- chamber dimension
- 600 X 900 X 1500
- temperature range
- 50 -134 Deg
- type of sterilizer
- Formaldehyde Sterilizer
- approval certificate
- CE Certificate
Add Quantity
Response within 4 hoursFree to enquire
Description
Chamber Capacity : 225 - 1000 Liters Door : Vertical Sliding / Radial Locking Double Door with Pneumatic OperationDoor Safeties : Cycle will not start until the door is shut properly, Door automatically stops if an obstruction is detected, Door cannot be opened when the chamber is pressurized, Prevents both doors from being opened simultaneously.Inner Chamber, Door, Steam Generator and Jacket : SS 316 LInsulation for Jacket and Doors : 60 mm Chloride free mineral wool.Pipes and Valves: Piping system made up of SS304 with Pneumatic Operated Piston type valve Steam Generator : Inbuilt Steam Generator made up of SS 316L, 50 mm Chloride free mineral wool, Safety Valve, Heating capacity of 45Kw.Vacuum Pump: High capacity efficient liquid ring type vacuum pump with Condenser for pre and Post Vacuum PulsingAutomatic Water Pump : High Pressure Feed water Pump for Automatic Water Filling.Operating Interface : Dual PLC control Based Fully Automatic HMI 7" Touchscreen on Both Loading and Unloading Side with COM ports for printer & PC communications, Password Protected, Data Logging facility, Different setting of cycles which are pre selectable and Editable as per User requirement, HMI displays Chamber Temperature, Pressure, Time, Date, Cycle No, Batch No, alert message with Audio visual alarm for Chamber and Steam Generator High Pressure and Temperature, Low Water level in Generator, Vacuum pump and Water pump error, Temperature and Pressure sensor failure.Automatic Program Cycles : 65oC Formalin Process, 80oC Formalin Process, 121oC Steam Sterilization Process, 134oC Steam Sterilization Process, Bowie-Dick Test, Leak Rate Test, Rapid Cooling process. Sensors : Two Temperature probes and Two Pressure Transducers for chamber and Jacket with temperature accuracy of ±0.1°C and pressure accuracy of 1%Formalin Injection : Through sealed bottle can be used for 2 cyclesPrinter: Alpha numeric Printer which prints whole cycle parameters Air Filter : HEPA air filter with 99.99% of efficiency for particle less than 0.3µm.Data logging : Can Be Viewed through HMI and also can be stored in the system through SD card.Jacket cooling system for sudden loading of LTSF from high Temperature Cycle.HCHO Monitoring the level and consumed quantity displayed at the End Cycle.
Verify supplier credentials before transacting. Enquiries create leads for the supplier.