AMF Control Panel
₹95,000.00
Specification
- phase
- Single-phase or Three-phase
- weight
- Varies by size and model
- display
- LCD/LED for system status and diagnostics
- humidity
- 0 to 95% non-condensing
- frequency
- 50Hz / 60Hz
- dimensions
- Depends on the model (HxWxD)
- indicators
- Mains on, generator on, fault indicators
- panel type
- AMF (Automatic Mains Failure) Pane
- availability
- In Stock
- cooling type
- Natural air cooling
- display type
- LCD/LED Display
- ethernet iot
- Remote control and monitoring over the internet
- power rating
- 10 kW to 1000 kW
- push buttons
- Manual override, reset, test buttons
- mounting type
- Wall-mounted / Floor-standing
- rs 485 modbus
- For remote monitoring and control
- voltage range
- 220V - 415V AC
- current rating
- 100A, 200A, etc. (Depends on the model)
- voltage rating
- 230V AC, 400V AC
- changeover time
- Less than 3 seconds
- changeover logic
- Automatic switching between mains and generator
- mains monitoring
- Voltage, frequency, and phase monitoring
- enclosure material
- Powder-coated steel or other durable materials
- overload protection
- Yes
- generator monitoring
- Voltage, current, power factor, etc.
- generator start stop
- Automatic start/stop on mains failure/restoration
- operating temperature
- -10°C to 55°C
- short circuit protection
- Yes
- phase imbalance protection
- Yes
- ingress protection ip rating
- IP54, IP65 (varies by model)
- over under voltage protection
- Yes
Add Quantity
Response within 4 hoursFree to enquire
Description
Voltage Rating 230V AC, 400V AC Frequency 50Hz or 60Hz Current Rating 100A, 200A, etc. (Depends on the model) Phase Single-phase or Three-phase Control Features Generator Start/Stop Automatic start/stop on mains failure/restoration Mains Monitoring Voltage, frequency, and phase monitoring Generator Monitoring Voltage, current, power factor, etc. Changeover Logic Automatic switching between mains and generator Communication Interfaces RS-485/Modbus For remote monitoring and control Ethernet/IoT Remote control and monitoring over the internet Protection Features Overload Protection Yes Over/Under Voltage Protection Yes Phase Imbalance Protection Yes Short-Circuit Protection Yes Display and Indicators Display Type LCD/LED Display Indicators Mains on, generator on, fault indicators Push-buttons Manual override, reset, test buttons Environmental Specifications Operating Temperature -10°C to 55°C Ingress Protection (IP Rating) IP54, IP65 (varies by model) Humidity 0 to 95% non-condensing Mechanical Specifications Dimensions Depends on the model (HxWxD) Weight Varies by size and model Enclosure Material Powder-coated steel or other durable materials
Verify supplier credentials before transacting. Enquiries create leads for the supplier.