eB2BMart

230 Volt Led Tube Bio Safety Cabinet Class 3

₹1,95,000.00

Specification

size
422
brand
Sterile Tech
class
Class III
model
SBC322 III
phase
single Phase
power
230 Volt
voltage
230 Volt
material
GI with PU coated
frequency
50 Hz
availability
In Stock
nominal size
4 ft
lighting type
LED Tube
biosafety level
BSL 3
surface treatment
Stainless steel 304
Add Quantity
Response within 4 hoursTo enquire

Description

Brand Sterile Tech Material GI with PU coated Size 422 Voltage 220 V Frequency 50 Hz Surface Treatment Stainless steel 304 Sterile Tech Class III, Bio Safety Cabinet offer the highest level of product, operator and environmental protection from infectious/ bio hazardous aerosols and are suitable for microbiological work with agents assigned to biological safety levels the Class III Bio safety Glove Box operates at a vacuum relative to the room with the service compartment under a slight vacuum. Room air enters the cabinet through a pre-filter into the service compartment where it is drawn through an inlet HEPA filter. Air exits the inlet HEPA into the work zone through a distribution manifold to promote a uniform flushing of the work zone to constantly purge the interior of contaminates. The contaminated air is drawn to the top of the work area where it is exhausted into the facility exhaust system. The interior of the cabinet is maintained at negative pressure by an optional motor blower or plant exhaust system.Designed around your Maximum Containment Research: Sterile Tech customization process starts at defining your specifications needed for your BSL-3 application. Our Class III Bio safety Cabinets offer maximum protection against pathogenic agents ensuring a gas tight working environment. Consider Sterile Tech Class III Glove Boxes when working with infectious agents, chemical carcinogens, aerosols, or high concentrations of low to moderate risk agents in microbiology, bacteriology, virology, culture analysis and more. How it Works: The Class III Bio safety Glove Box operates at a vacuum relative to the room with the service compartment under a slight vacuum. Room air enters the cabinet through a pre-filter into the service compartment where it is drawn through an inlet HEPA filter. Air exits the inlet HEPA into the work zone through a distribution manifold to promote a uniform flushing of the work zone to constantly purge the interior of contaminates. The contaminated air is drawn to the top of the work area where it is exhausted into the facility exhaust system. The interior of the cabinet is maintained at negative pressure by an optional motor blower or plant exhaust system. Monolithic Pressure Tight Construction: A single shell, high grade stainless steel, fully welded cabinet eliminates potential leaks that may occur through failures of gaskets and cabinet seams. Technical Details: Sterile Tech Model No SBS 322(III) SBS 422(III) SBS 622(III) Working Size (L x W x H) Ft 3'x2'x2' 4'x2'x2' 6'x2'x2'

Verify supplier credentials before transacting. Enquiries create leads for the supplier.