AGD Fully Automatic Biochemistry Analyzer Dia Chem 240 plus, Assays: Clinical Chemistry, Centrifugal analyzers

₹5,60,000.00

Specification

lamp
Tungsten halogen lamp
type
Centrifugal analyzers
brand
AGD
assays
Clinical Chemistry
automation
Fully Automatic
model name
AGD 2260
throughput
Up to 260 tests per hour
availability
In Stock
power supply
240 V ,50-60 Hz
9 wavelengths
300 to 700nm
laundry system
Needles: 8 step washing sequence. Water Consumption: Upto 4 l/ hr
optical system
Independent mixing probe
reaction system
90 special cuvettes Length of Cuvette: 6mm Reaction Volume: 200μL to 500μL Reaction Time: 8 to 10 mins Reaction Temperature: 37°C ±0.1°C
absorbance range
0 to 4.00Abs
reaction cuvette
Reusable Cuvette
spectrophotometry
Rear spectrophotometry
sample arrangement
40 positions for sample, STAT, Calibrator and QC Sample Volume: 2μL to 50μL, step by 0.1μL Compatible with primary collection tube, minimal tube, sample cup, etc.
reagent arrangement
40 reagent positions for R1 and R2 Volume Range: 10μL to 500μL, step by 1μL Reagent Probe: Liquid level detection, collision protection function On board cooling (2°C to 8°C)
measuring principles
Absorbance Photometry, Turbidimetry, End-point, Two-point, Kinetic /Dual/ Reagent Chemistry, Monochromatic/ Bichromatic
Add Quantity
Response within 4 hoursTo enquire

Description

Technical Specifications ParameterDescription Throughput Up to 260 tests per hour Measuring Principles Absorbance Photometry, Turbidimetry, End-point, Two-point, Kinetic /Dual/ Reagent Chemistry, Monochromatic/ Bichromatic Sample Arrangement 40 positions for sample, STAT, Calibrator and QC Sample Volume: 2μL to 50μL, step by 0.1μL Compatible with primary collection tube, minimal tube, sample cup, etc. Reagent Arrangement 40 reagent positions for R1 and R2 Volume Range: 10μL to 500μL, step by 1μL Reagent Probe: Liquid level detection, collision protection function On board cooling (2°C to 8°C) Laundry System Needles: 8 step washing sequence. Water Consumption: Upto 4 l/ hr Reaction System 90 special cuvettes Length of Cuvette: 6mm Reaction Volume: 200μL to 500μL Reaction Time: 8 to 10 mins Reaction Temperature: 37°C ±0.1°C Optical System Independent mixing probe 9 wavelengths 300 to 700nm Absorbance range 0 to 4.00Abs Spectrophotometry Rear spectrophotometry Lamp Tungsten halogen lamp * Specifications are subject to change without prior notice.