eB2BMart

Power Line Transducers

Price on request

Specification

time
Response Time < 250 ms for 0 to 90% of Output < 1 s for 0 tp 90% of Output for PF Warm Up Time 20 min. (approx.)
overload
Continuous - Voltage : 1.2 x Un &nbsp
availability
In Stock
output ripple
< 0.5% of Full Scale
accuracy range
0 to 120% &plusmn;0.5% of Span (standard) Others on request (optional)
compliance voltage
12V DC (max.)
application standards
IEC 688 / EN 60688 Electrical Measuring Transducers for converting AC Electrical Quantities to Analog or Digital Signals. EN 61010-1 Safety requirments for Electrical Equipment for Measurement Control
zero amp span adjustment
Zero Adjustment : &plusmn; 2% of Span (min.) Span Adjustment : &plusmn; 10% of Span (min.)
environment conditions as per iec 688 user group ii
Operating Temperature 0 to 55 &ordm;C, RH < 95% (non condensing) Storage Temperature -20 to 70 &ordm;C, RH < 95% (non condensing) Calibrated At 27 &ordm;C &plusmn; 5 &ordm;C Temperature Coeficient 0.0
Add Quantity
Response within 4 hoursFree to enquire

Description

Models: General Specification of TransducersFeatures: Terminal Protection Cover Reliable & Rugged Static Circuits Low Ripple in outputs Signal Flame Retardant Polycarbonate case Choice of Multiple Asymmetrical Outputs Wide Choice of Suppressed Ranges Open and Short Circuit Protection for Outputs Dual Outputs (Non Isolated / Isolated) Self – Powered, AC, DC Auxiliary Supply Bi-directional Output Fast Response Time Din-Rail Mounting Bi-Directional Inputs for Import / Export input Accuracy range 0 to 120% ±0.5% of Span (standard) Others on request (optional) Time Response Time < 250 ms for 0 to 90% of Output < 1 s for 0 tp 90% of Output for PF Warm Up Time 20 min. (approx.) Compliance Voltage 12V DC (max.) Environment Conditions (As per IEC 688 User group II) Operating Temperature 0 to 55 ºC, RH < 95% (non condensing) Storage Temperature -20 to 70 ºC, RH < 95% (non condensing) Calibrated At 27 ºC ± 5 ºC Temperature Coeficient 0.02% / ºC Application Standards IEC 688 / EN 60688 Electrical Measuring Transducers for converting AC Electrical Quantities to Analog or Digital Signals. EN 61010-1 Safety requirments for Electrical Equipment for Measurement Control & Laboratory use. EN 61326-1 Electrical Equipment for Measurement Control & Laboratory use - EMC requirements IS 12784 (Part-1)1989 Electrical Measuring Tranducers for converting AC Electrical Quantities into DC Electrical Quantities : General Purpose Transducers Zero & Span Adjustment Zero Adjustment : ± 2% of Span (min.) Span Adjustment : ± 10% of Span (min.) Output Ripple < 0.5% of Full Scale Overload Continuous - Voltage : 1.2 x Un Current : 2 x In Short Duration - Voltage : 2 x Un (1 sec) Current : 20 x In Max. Open Current Voltage : < 30V DC We are majorly looking for queries from Madhya Pradesh, Chhattisgarh, Maharashtra, Orissa, Andhra Pradesh and Rajasthan.

Verify supplier credentials before transacting. Enquiries create leads for the supplier.