eB2BMart

3M Super 88 vinyle Electrical Tape (38 MM X 36 YD), 32.9M

₹850.00

Specification

brand
3M
color
Black
width
3.8 cm
length
3290 cm
thickness
0.022 cm
tape width
3.8 cm
roll length
32.9MTR
availability
In Stock
adhesive type
Rubber Based
flame retardant
Yes
Add Quantity
Response within 4 hoursFree to enquire

Description

Scotch® Vinyl Electrical Tape Super 88 is a black, professional grade, nominal 8.5-mil (0.216 mm) thick electrical insulating tape composed of an elastic vinyl (PVC) film backing coated on one side with a non-corrosive, rubber-based pressure-sensitive adhesive. UL510: As primary insulation on applications up to 600V at max temperature of 80°C (176°F) and min temperature of -10°C (14°F) on joints and splices in wires and cables in accordance with NFPA 70, National Electrical Code  CSA C22.2 No.197: As primary insulation on applications up to 1000V at max temperature of 105°C (221°F) and a min temperature of -18°C (0°F) on joints and splices in wires and cables in accordance with Canadian Electrical Code, Part 1  IEC 60454-3-1: Classification Type 7, Designation IEC 60454-3-1-7/F-PVCP/90 for thermal index of 90°C (194°F) and min temperature rating of -18°C (0°F)  Industrial, commercial and residential environments  Where Flame Retardant and Sunlight, Cold Resistance rating is required – UL510  Cable jacket repair (up to 600V (UL) / 1000V (CSA) as primary insulation) and as mechanical protection when overwrapping rubber splicing, and mastic tapes used on LV/MV/HV joints and splices  Critical indoor and outdoor operations as determined by end-user where use of a general use vinyl electrical tape is not recommended  Where compatibility with solid dielectric cable insulations, rubber and synthetic splicing compounds is required  Where reducing moisture ingress is needed, best results achieved when used as an overwrap in combination with a rubber splicing or mastic tape product  For harnessing and bundling of wires and cable where faster build-up is needed Primary Insulation: Used for wire and cable splices up to 600V. Protective Jacketing: Ideal as an outer layer for low- and high-voltage bus applications to guard against environmental damage. Harnessing and Bundling: Used for wire and cable harnessing where faster insulation build-up is required. Corrosive Environments: Protects electrical conductors in industrial, marine, and underground environments.

Verify supplier credentials before transacting. Enquiries create leads for the supplier.