eB2BMart

Semi Automatic Electrolyte Analyzer

₹75,000.00

Specification

brand
AGD ERMA EL 120
usage
Laboratory
display
5" color LCD with Touchscreen Display, Resolution: 480 x 272 pixels
printer
Built-in 2" (48 mm) Thermal Printer, 42 characters wide
precision
CV % Na+ : ≤ 2% K+ : ≤ 2% CI- : ≤ 2% iCa++: ≤ 3% pH : ≤ 2%
principle
Ion selective Electrode (ISE)
automation
Semi Automatic
parameters
Na+, K+, CI-, iCa++& pH
throughput
≤ 60 samples per hour
calibration
Automatic Calibration: User-defined two-point calibration interval - 4 hours / 8 hours / 12 hours One Point Calibration with each sample analysis
availability
In Stock
sample types
Serum, Plasma, Whole Blood, Urine, CSF
analysis time
≤ 60 secs
normal ranges
User defined normal ranges for all sample types with flagging for abnormal samples
sample volume
≤ 90µL
sample storage
10,000
data management
Calibration History, Sample History and Control History of last 30 days
quality control
Tri-Level Quality Control, with L J Plots of last 30 days
automation grade
Semi Automatic
country of origin
Made in India
model name number
ERMA EL 120
external interface
USB (Mouse, Keyboard, Barcode reader, Pen drive)
accepts sample from
Whole Blood/Serum/Plasma/Urine/CSF
Add Quantity
Response within 4 hoursFree to enquire

Description

Salient Features Na+, K+, CI–, iCa++ & pH Low sample volume and cost per test Onboard reagent tracking system Calibration interval after 4 hrs. / 8 hrs. / 12 hrs. In-built quality control with LJ plots Large touchscreen display with graphical user interface Technical Specifications ParameterDescription Principle Ion selective Electrode (ISE) Sample Types Serum, Plasma, Whole Blood, Urine, CSF Parameters Na+, K+, CI-, iCa++& pH Sample Volume ≤ 90µL Analysis Time ≤ 60 secs Throughput ≤ 60 samples per hour Precision CV % Na+ : ≤ 2% K+ : ≤ 2% CI- : ≤ 2% iCa++: ≤ 3% pH : ≤ 2% Calibration Automatic Calibration: User-defined two-point calibration interval - 4 hours / 8 hours / 12 hours One Point Calibration with each sample analysis Normal Ranges User defined normal ranges for all sample types with flagging for abnormal samples Data Management Calibration History, Sample History and Control History of last 30 days Quality Control Tri-Level Quality Control, with L J Plots of last 30 days Display 5" color LCD with Touchscreen Display, Resolution: 480 x 272 pixels Sample Storage 10,000 Printer Built-in 2" (48 mm) Thermal Printer, 42 characters wide External Interface USB (Mouse, Keyboard, Barcode reader, Pen drive) * Specifications are subject to change without prior notice.

Verify supplier credentials before transacting. Enquiries create leads for the supplier.

Semi Automatic Electrolyte Analyzer - ₹75,000.00 | MEDIPRO MEDICAL SYSTEMS | eB2bMart