Flame Photometer
₹20,001.00
Specification
- brand
- khera
- accuracy
- +-2 % upto 40 ppm
- mobility
- Benchtop
- sensitivity
- 0.5 ppm
- availability
- In Stock
- model name number
- KI-269(b)
- curve fit accuracy
- +- 2% of F S
Add Quantity
Response within 4 hoursFree to enquire
Description
General Range Serum Range Urine RangePpm meq/l meq/lNa : 0-100 0-200 meq/l, 1:100 dil. 0-250 meq/l, 1:100 dil.K : 0-100 0-10 meq/l, 1:100 dil. 0-100 meq/l, 1:100 dil.Ca : 0-100 0-10 meq/l, 1:2 dil.Li : 0-100 0-2 meq/l, 1:5 dil.Ba : 30-3000 (all meq values are claimed with appropriate dilution)SENSITIVITY : General Mode : Na 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm Ba: 30 ppmFILTERS : Na & K Supplied (Ca, Li & Ba are optional at extra cost) & Factory Fitted onlyRESOLUTION : 0.1 ppm / 0.1 meq.REPRODUCIBILITY : < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as Maximum Standard up to 3% CV for 20 consecutive samples of Concentrations between 50 to 199 ppm for Barium.LINEARITY : < 2% error when 3 ppm Na/K and 5 ppm Li are set as Maximum Std.CURVE FIT ACCURACY : ± 2% of FSDISPLAY :128 X 64 Graphical LCDAVERAGE TIME : In –built in SoftwareFLAME SYSTEM : LPG & Dry Oil Free AirDETECTOR : PhotodiodeCALIBRATION : with up to 25 Standards of user choice with curve fitting software (5 for each Element). Multiple Calibration Curves can be stored in the memoryGAS CONTROL : Adjustable with knobASPIRATION TIME : 3 ml per MinuteFLAME FAILURE : Auto DetectionGAS CUTT OFF : AutomaticIGNITION SYSTEM : Auto IgnitionAUTOMISER : Axial Flow TypeDIMENSIONS : Instrument : 365 x 245 x 220 mm Approx. (LxBxH)PC INTERFACE : USBWEIGHT : Main Unit : 8 Kg. (Approx.)POWER SUPPLY : 230 V AC ± 10%, 50 Hz SALIENT FEATURES Auto Gas Cut off FacilityAuto Flame Failure Detection FacilityInbuilt Thermal Printer (In Model 672)µP Based With Printer InterfaceFive Element Measurement In Single Aspiration of the SampleCurve Calibration Programmability using Maximum of 25 StandardsData Processing Through Curve Fitting Techniques- Least Squares, QuadraticMultiple Calibration Curves Saving FacilitySamples Data Storage FacilityOnline Help KeyPrinter Attachment FacilityMeasurement in ppm & meqUseful For Both Medical & Soil Testing ApplicationsSetup Storage Facility up to 10 setups filesSupplied with Compressor UnitSTANDARD ACCESSORIESAir CompressorChimneySample BeakersManualAir & Gas TubingUSB CablMain Lead
Verify supplier credentials before transacting. Enquiries create leads for the supplier.