Specification

brand
Mechmatics
venturimeter
Clear Pespex
orfice diameter
16 mm
throat diameter
16 +/-1 mm
variable area meter
100-1000 LPH
upstream pipe diameter
25 +/-1 mm
Add Quantity
Response within 4 hoursFree to enquire

Description

Pipe Losses (Major-Minor) Flowmeters (Orifice-Venturimeter and Rotameter) Pressure Measurement 5-in-1 Comined Fluid Mechanics Features : SHS- 40 Frame with Metal Coat Paint Reservior Tanks Made of SS-304 All Wooden Boards are Laminated Storage Cub-board provided Pumps with on-site service Warranty. Plumbing is of FINOLEX make. Electrical Accessories of ANCHOR All Machining parts Crome Coated. Friction Losses in Pipes This equipment allows the pressure drop of water passing through a hydraulically smooth circular pipe to be measured in detail and the pipe friction equation should be to be verified. The energy losses in pipes accessory consists of a test pipe, on the side of the equipment, which may be fed directly from the common supply tank. These sources provide high or low flow rates which may be controlled by a valve at the discharge end of the test pipe. Head lost between two tapping points in the test pipe is measured using manometer. Specifications : Pipe : �� ; �� and 1� standard UPVC Test length: 1000 mm Energy Losses in Pipe Fittings This accessory permits measurement of losses in different pipe fittings. The equipment is mounted on a free standing framework which supports the test pipe work and instrumentation. The following typical pipe fittings are incorporated for study: miter bend, 90 elbow, sudden contraction and enlargement and Gate valve. All are instrumented with upstream and downstream pressure tappings. These tappings are connected to manometer tubes using removable PU pipes, mounted on the framework. A gate valve is used to control the flow rate. Specifications : Pipe Diameter : 1� Standard UPVC Fittings : Bend, elbow, Valve, long bend, Enlargement & Contraction. Flow measurement Devices This accessory should be designed to introduce students to three basic types of flow meters: Venturimeter Rotameter or Variable area meter Orificemeterplate. (Optional Nozzlemeter or Flow nozzle) A flow control valve permits variation of flow rate through the circuit. Pressure tapings are incorporated so that the head loss characteristics of each flow meter may be measured. These tapings are connected to manometer with air bleed valve. The circuit and manometer are attached to a support framework which stands on the working top of the setup. The bench is used as the source of water supply and for calibrating volumetrically each flow rate. Aim is to measure the Discharge coefficient of each of the flowmeters. Study of Pressure Measuring Devices The Set � Up Consist Of Different Pressure Measurement Device Fitted on a board. The Students Can Have Good Insight Of The Devices. It can be used to Demonstrate The Working Of Different Pressure Measuring Devices and to Measure The Pressure Practically By Different Pressure Measuring Devices. A hand held syringe is provided to generate Vacuum and create pressure for Sensitive manometer. Specifications : Differential Manometer : U Tube Type Sensitive Manometer : Inclined Tube Type Pressure Gauge : Bourdon Tyoe Vacuum Gauge : Bourdon Type

Verify supplier credentials before transacting. Enquiries create leads for the supplier.

Fluid Flow and Losses Measurement - ₹60,000.00 | Mechmatics Engineering Pvt Ltd | eB2bMart