eB2BMart

Centrifuge Machine for Sediment Testing in Petroleum Oil as per ASTM (Optional Heating)

₹4,86,000.00

Specification

type
Swing Out Rotor
brand
Haico
speed
4000
voltage
220 V AC
capacity
100ml x 4 nos. (max.)
material
Mild Steel
availability
In Stock
is it portable
Non Portable
size dimension
700 x 600 x 400
Add Quantity
Response within 4 hoursTo enquire

Description

Haico conforms to the following ASTM standards, ASTM D91 - ASTM D96 - ASTM D893 - ASTM D1796 - ASTM D2273 - ASTM D2709 - ASTM D2711 - ASTM D4007 - ASTM D5546 - API 2542 - API 2548 - BS 4385 - ISO 3734 - ISO 9030 - IP 75 - IP 359 - NFMO 7020. This Oil Test Centrifuge is fully programmable allowing automatic configuration to the specified oil test parameters.This centrifuge is specially designed for water and sediment determination, as well as characterization of used oils and petrol features like demulsibility and precipitation. Available are accessories for 6" and 8" cone-shaped centrifuge tubes, pear-shaped centrifuge tubes. Heating - Preheating program with rotor spinning and temperature is selectable by operator. - Temperature regulation from ambient +5°C up to +80°C (176°F). - Scale Celsius or Fahrenheit. - Temperature sensor in the chamber.User friendliness - TFT touch screen, easy to read and values selection. - Informative display about the progress of stages of centrifugation. - Rotor and adapters list in memory. - Real values on screen of RCF based on accessories configuration. - Start delay - Unbalancing locations system (ULS)- Timer count up/down, for 0 or at "set RPM/RCF" for test reproducibility. From 1 minute to 99 hours, in 1 second steps, and hold position. - Up to 175 acceleration ramps and up to 175 breaking ramps. - Automatic rotor recognition. - Lid latch lock. - Microprocessor controlled. - Induction motor, maintenance free - Up to 4000 RPM/ 2.425 RCF (9 RPM/9 xg steps) Safety - Isolation for reducing the heat loss. - Lid locking and holding. - Imbalance switch-off. - Manual overriding and lid dropping protection. - Chamber of centrifugation made from stainless steel. - Several Programs to keep the operator trouble free about varius Tests. - Guard ring between the chamber of centrifugation and the housing. Specifications: Max speed 4000rpm Max RCF 2498xg Max volume 4x100ml Noise ≤60dBA Timer 1~99min Net weight 67KG Dimension(LxWxH)mm 685×500×405mm Temperature Range Room temperature:+10~80℃ Speed accuracy ±20rpm Package Wooden box

Verify supplier credentials before transacting. Enquiries create leads for the supplier.