Table Top HANNA Benchtop pH/mV Meter with Manual Calibration - HI2209, For Laboratory, 0.01 Ph
₹28,975.00
Specification
- brand
- Hanna
- usage
- Laboratory
- accuracy
- 0.01 pH
- mv range
- +-1999 mV
- resolution
- 0.01 pH
- availability
- In Stock
- model number
- HI2209-01
- packing type
- Box
- ph electrode
- HI1332B PEI body pH electrode with BNC connector and 1 m (3.3') cable (included)
- type of ph meter
- Table Top
- model name number
- Benchtop pH/mV Meter with Manual Calibration - HI2209
- automatic ph calibration
- Manual, one or two-point
- ph temperature compensation
- manual from 0 to 100 DegreeC (32 to 212 DegreeF)
Add Quantity
Response within 4 hoursTo enquire
Description
The HI2209 is a basic, affordable pH/mV benchtop meter designed for simplicity of use. Manual calibration can easily be performed to 1 or 2 points with the help from the meter's built-in solution holders. The meter has a large, easy-to-read LCD that displays pH or mV readings that are manually compensated for temperature variations. The HI2209 is supplied with the HI1332B PEI plastic body, gel filled, double junction pH electrode. Large, Clear Display Universal BNC Connection Built-In Solution Holders Features at-a-glance Simple User Interface – Operation is simple with limited features that only require the use of several front panel knobs. Readings are easy to view on the large, clear display. One or Two-Point Calibration – Manual calibration can be performed at 1 or 2 points on the HI2209. This simple feature allows demonstration of the concepts of offset and slope. The HI2209 can be calibrated to any value within the measurement range of 0.00 to 14.00 pH. HI1332B pH Electrode – The HI2209 is supplied with the HI1332B plastic PEI body, double junction pH electrode with an indicating sensor made of General Purpose (GP) glass. The durable body and GP glass design allows the HI1332B to be used in a wide variety of applications, from chemical samples to field use and quality control. Temperature Compensation – Manual temperature compensation provides the ability to demonstrate the effect of temperature on pH measurements. Manual correction for temperature with the HI2209 is simple to use and allows for temperature corrections ranging from 0 to 100℃ based on the sample being tested. Built-In Solution Holders – The HI2209 benchtop meter features solution holders built directly into the casing. This convenient feature saves valuable benchtop space and maintains solution bottles in an upright position, avoiding any potential spills.
Verify supplier credentials before transacting. Enquiries create leads for the supplier.