Missing Bucket Detector for Bucket Elevator

₹17,000.00

Specification

features
Missing Bucket Detector
material body
Metal
model name number
MBD
utilization category
Safety Switch
environmental sealing
IP 65
operating temperature
Upto 75 Degree Cent
short circuit protective device
Yes
Add Quantity
Response within 4 hoursFree to enquire

Description

SMARTsaa Instruments I Pvt Ltd has developed Missing Bucket Detector for Bucket Elevator. These sensors find application on bucket elevator to detect missing buckets. As the bucket elevator speed is constant the time gap between two passing bucket is also constant. Extended range proximity sensors are mounted on the side of the casing. The bucket when passes in front of the sensor a pulse is generated. The sensor gives command to a pulse evaluation circuit. When the time between two passing buckets exceeds a control action is generated. Specification: Sensor: · Supply: 10-30 V DC · O/P: PNP or NPN, NO + NC · Load current: 200 mA · Size: Rectangular Block type with mounting bracket and gasket · Object sensed: Any Ferromagnetic minimum size 150 x 150 x 2 mm · Sensing Range: Up to 80 mm · Max operating frequency: 100 Hz · Operating Temp: 70 degree cent · Enclosure: ABS Plastic, IP 67 Control Unit: · Supply: 230 V AC · O/P: 2 C/O Relay Contact for field Mounting / 1 C/O relay contact for Panel Mounting · Contact rating : 5 Amp resistive at 230 V AC · Enclosure: Cat Al , IP 65 / IP 30 Panel Mounting 48 x 96 size · With pulse gap adjustment potentiometer OPERATING LOGIC: The Sensors senses the bucket and when bucket passes in front of sensor, a pulse is generated. This pulse is fed to control unit. The control unit measures time gap between the bucket and when the time gap exceeds set value, the relay actuates. Relay -On Time: After actuation, the relay will remain OFF for time set. Relay –On Time range: 0-999 m Sec adjustable. The signal latching circuit is to be designed by customer at PLC or Panel end. After this delay, if controller start receiving pulses at desired interval, the relay gets ON. Design Criteria: As given by you No Of Buckets Passing in front of sensor per second : 3- 4 Normal Time Gap between two buckets : 332 m Sec - 250 m Sec Settable time Gap range : 0-999 m Sec ITD: Initial Bypass Time Delay: Range 0-999 m Sec. This delay will come in picture when the controller is powered. As initially when Bucket Elevator is given supply, it is at standstill. This ITD will allow the bucket elevator to achieve normal speed. You need to design control circuit such that, when bucket elevator is Powered ON, Missing Bucket Detector gets power simultaneously.

Verify supplier credentials before transacting. Enquiries create leads for the supplier.

Missing Bucket Detector for Bucket Elevator - ₹17,000.00 | Smartsaa Instruments (I) Private Limited | eB2bMart