Flameproof Metal Tube Rotameter, 25 NB, Flow range: 100-1000 LPH
₹27,000.00
Specification
- usage
- Industrial Use
- flow rate
- 100 - 1000 LPH
- line size
- 25 NB
- flow range
- 100-1000 LPH
- power supply
- 24 V DC
- working temp
- 120 °C
- body material
- SS316
- output signal
- 4-20 mA + HART
- process fluid
- Water
- range ability
- 1000 LPH
- end connection
- Flanged
- indicator type
- Local with transmitter
- working pressure
- 16 bar
- country of origin
- Made in India
- housing protection
- Flameproof
- tube body construction
- Stainless Steel
Add Quantity
Response within 4 hoursTo enquire
Description
Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth, the movement of the float is accurately indicated in terms of flowrate. They are intended for application where high pressure, temperature or corrosive conditions preclude the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate.When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is created between upper and lower side of the float. The float moves upwards by a force obtained by multiplying the pressure differential by the maximum cross-sectional area of the float.Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus giving birth to flow rate indication. Accuracy : ± 2% of FSD Rangeability : 10:1 Repeatability : ± 0.5% Temperature Rating : -20 to 250°C Pressure Rating : 40 Bar Flow Direction : Bottom to Top Connections : Flanged, TC End and Screwed Connection Size Available : 15 NB to 150 NBEnclosure : IP 65 Weatherproof / Flame Proof
Verify supplier credentials before transacting. Enquiries create leads for the supplier.