Specification

gas
LPG,NATURAL GAS , OXYGEN, NITROGEN,AMONIA
brand
MADAS
media
Gas
usage
Industrial
gas type
LPG / NATURAL GAS / BIO GAS
material
Brass
port size
4 inch
structure
Control
with tube
Yes
valve type
SOLENOID VALVE
availability
In Stock
inlet pressure
100 PSI
regulator type
High Pressure Regulator
Add Quantity
Response within 4 hoursTo enquire

Description

Energy Combustion, Importer and Supplier of Madas brand components in India.The Madas RG (Pressure Regulator) and MVB (Slam-Shut Valve) are complementary devices often used together in gas trains to ensure stable delivery and safety. While the RG series maintains a constant downstream pressure, the MVB series acts as a "safety sentinel" that triggers a hard shutdown if pressures go out of bounds. 1. Madas RG Series Data Sheet (Regulators) The RG series is characterized by a "compensated obturator" which ensures that the outlet pressure remains stable even if the inlet pressure or flow rate fluctuates sharply. Technical Features Media: Natural gas, LPG, and non-aggressive dry gases. Ambient Temp (Ts): -15°C to+60°C. Inlet Pressure (P1): From 500 mbar up to 5 bar (model dependent). Accuracy Class (AC): 10-15%. Lock-up Class (SG): +30. Filtration: None (The RG is the regulator-only version; see the FRG for the filter-integrated version). Core RG Models Model P1​ Range Standard Features Connection Sizes RG/2MT 500 mbar Compact; for small users. DN 15 – 25 RG/2M 500 mbar Safety membrane; compensation. DN 15 – 150 RG/2MC 0.5 to 2 bar High precision; compensated. DN 15 – 150 RG/2MB 0.5 to 5 bar Integrated OPSO/UPSO/Relief. DN 15 – 100 2. Madas MVB Series Data Sheet (Slam-Shut Valves) The MVB series is a safety device that automatically shuts off the gas flow. Unlike a regulator, it has two states: Fully Open (normal operation) or Tripped/Closed (after a fault). Technical Features Function: OPSO (Over Pressure) or UPSO (Under Pressure). Response Time: < 1 second. Reset Type: Manual only. You cannot reset an MVB until the pressure has returned to normal and the cause is identified. Standard Set Range: 30-450mbar (adjustable). Maximum Pressure (P{max}): 1bar or 6 bar. MVB Model Variants Model Trigger Condition Safety Goal MVB/1 MAX P2 Set Point Protects downstream equipment from overpressure. MVB/1 MIN P2 Set Point Protects against line breaks or upstream gas failure. 3. Comparison & Integration In a standard industrial gas train, these components are installed in a specific sequence to protect the system: Filter (FM): Removes debris. Slam-Shut (MVB): Protects against regulator failure. Regulator (RG): Drops the pressure to the burner's requirement. Solenoid Valve (EVP): For operational on/off control. Installation Guidelines Orientation: Preferred horizontal with the spring tower/lever facing upwards. Venting: For high-pressure models, the relief valve (if present) may need a vent pipe to the outdoors. Sizing: Always size based on flow capacity (Q), not just pipe diameter. An oversized regulator can cause "hunting" (unstable pressure).

Verify supplier credentials before transacting. Enquiries create leads for the supplier.

MADAS Gas Pressure Regulator / Slam Shut Off Valve - ₹3,650.00 | Energy Combustion | eB2bMart