Single Core X 95 Sq.mm Solar DC Cable Exbl
₹1,680.00
Specification
- type
- Double Insulated Cable
- coating
- XLPE XL
- ideal for
- Solar Panel
- jacket type
- LSZH
- availability
- In Stock
- conductor type
- CLASS5
- outer material
- ZHFRD
- packaging type
- COILS
- number of wires
- SINGLE CORE
- conductor material
- ATC COPPER CONDUCTOR
- insulation material
- EBEAM
Add Quantity
Response within 4 hoursFree to enquire
Description
Solar DC Cable Products RangeApplications These cables are designed for connecting photovoltaic power supply systems. These cables can be used indoor & outdoor for flexible and fixed installations with high mechanical strength in extreme weather conditions. Standards 2 Pfg 1169/08.2007. Electrical Characteristics Rated Voltage: 0.6/1 kV AC Rated DC Voltage: 1.5 kV Maximum Permitted DC Voltage: 1.8 kV (conductor/conductor, non earthed system, circuit not under load) Maximum Permitted AC Voltage: 0.7/1.2 kV Working Voltage: DC 1000 V Insulation Resistance: 1000M Q – km Spark Test: 6000 Vac (8400 Vdc) Voltage Withstand: 6500 V as per EN50395 for 5 min Ampacity: According to requirements for cables for PV systems Conductor : Electrolytic Multi Stranded tinned copper conductor flexible as per IEC 60228 Class 5. Insulation : Crosslinked Halogen Free & Flame Retardant Insulation Sheath : Sheath Crosslinked Halogen Free & Flame Retardant Sheath in Black/Blue/Red ColourNote : Insulation thickness, Sheath thickness and Overall Dimensions given in this table are nominal values. The strand diameter is nominal. However, Construction of the conductor is designed to satisfy the requirement of conductor resistance as per IS 8130 :1984.Thermal Characteristics Ambient Temperature: -40°C ~ +90°C Maximum Temperature at Conductor: 120°C (20000h) Short Circuit Temperature: 200°C (at conductor max. 5sec) Thermal Endurance Test: According to EN 60216-2 (temperature index +120°C) High Temperature Pressure: Test according to EN 60811-3-1 Damp – Heat Test: According to EN 60068-2-78 1000 hrs at 90°C with 85% humidity Mechanical Characteristics Minimum Bending Radius: 5 x OD (fixed), 15 x OD (occasional flexing) Dynamic Penetration: According to requirement of Cables for PV systems 2 Pfg 1169/08.2007 Annex F Notch Propagation: According to 2 Pfg 1169/08.2007 Annex G Tensile Strength: 6.5 N/mm2 for insulation and 8 N/mm2 for sheathing – according to EN60811 Elongation of Insulation and sheathing: 125% – according to EN60811 Anticipated Period of Use: 25 years Shrinkage: 2% at 120°C according to EN60811-1-3
Verify supplier credentials before transacting. Enquiries create leads for the supplier.