Photo Stability Chamber
Price on request
Specification
- gmp model g
- Inside S.S. 316 with mirror polish & outside stainless steel 304 with dull buff finish.
- availability
- In Stock
- standard model s
- Inside S.S. 304 with mirror polish & outside mild steel powder coated.
Add Quantity
Response within 4 hoursFree to enquire
Description
Technical SpecificationTemp. Range : 20°C to 60°CTemp. Accuracy : ± 0.2°CTemp. Uniformity : ± 1°CHumidity Range : 40% Rh to 90% RhHumidity Accuracy : + 2 % RhHumidity Uniformity : + 3 % RhFluorescent tube for day light effect and UV tubes for Ultra Violet ray in accordance to the ICH guidelines requirement of a lightning energy mounting to 1.2 mil lux per hours and integrated UV energy share of 200 Watt Hours per mtr sqr.As per ICH guidelines : At 25°C : RH = 60%At 30°C : RH = 65%At 40°C : RH = 75%Standard Model (S)Inside S.S. 304 with mirror polish & outside mild steel powder coated.GMP Model (G)Inside S.S. 316 with mirror polish & outside stainless steel 304 with dull buff finish.Double walled construction with backside triple.3" Thick PUF Insulation ensures stable temperature with reduced energy consumption.Motorized Blower at back side of the chamber develops unique air flow system which ensures maximum uniform temperature & humidity condition inside the chamber.U nique air flow assures quick recovery after door openings.1/12 HP, TEFC , F-class insulation, Single phase, 1440 RPM, 230 VoltsHigh quality U shape S.S. Tubular Heaters are used for better heating.Steam injection system (Non condensing type) & reservoir tank with water level arrangement with indicator.Temperature ControlTemperature Control : By means of Imported Microprocessor based auto tuned PID controller with CE mark & dual display of set value & process value.Humidity ControlHumidity Control & Sensing : By means of Imported Microprocessor based auto tuned PID controller with CE mark & dual display of set value & process value with direct % RH.Direct RH electronic capacitor type humidity sensor, avoid wick cup & water.Safety FeaturesAdditional Safety thermostat to cut of dry heater supply in case temperature of overshoot.Float switch to cutoff the wet heater supply in case of low water level. Audio & Visual alarm.Compressor ON delay timer (2 min.) to safe guard the compressor.In built over load protector provided for hermetically sealed compressor.Refrigeration SystemRefrigeration by means of CFC Free hermitically sealed Emerson Copland make compressor with R 134A for better cooling with ECO friendly refrigerant with time delay to safe guard compressor system.
Verify supplier credentials before transacting. Enquiries create leads for the supplier.