Manti Microprocessor Water Testing Kit
₹25,000.00
Specification
- brand
- MANTI
- light
- 6.8V Tungsten Lamp
- model
- MT-130
- range
- 0 to 14pH
- buffer
- Manual By Keys
- display
- 16 Character * 2 lines Alphanumeric lcd.
- setting
- By soft Touch Keys
- storage
- 1000 samples With Date and Time
- accuracy
- ±0.01pH (Relative)
- material
- Plastic
- i deal in
- New Only
- interface
- RS-232 Centronics Computer
- temp comp
- Automatic With Temp. Probe
- input type
- Pt 100
- resolution
- 0.01pH
- tds factor
- 0.5 and adjustable manuall
- accessories
- 1) pH Electrode2) Standard Solution 7.0 pH 4.0 pH3) ORP Electrode (On Demand)4) Temeprature Probe5) Conductivity/TDS/Salinity Cell6) DO Probe7) Instruction Manual
- application
- pharmaceutical, Laboratory Use, Industrial Use
- calibration
- Auto/Manual 2-Point, 3-Point
- recognition
- 4.00 7.00, 9.20 pH (Automatic)
- sample size
- 30mm glass tube
- availability
- In Stock
- print format
- ALL DATADATE WSIE
- cell constant
- Adjustable
- digital output
- SERIAL RS-232PARALLEL CENTRONICS
- display format
- Temp pH or temp ORP Simultaneously auto Display of Selected Buffer
- mv calibration
- Manual
- range selection
- Automatic
- salinity factor
- 0.75 and Adjustable Manually
- error indication
- pH error , Buffer Error , ORP Error
- slope adjustment
- 80% to 120%, By Default 100%
- temperature comp
- Automatic
- country of origin
- Made in India
- real time display
- 24 hour Mode With Date
- temperature co eff
- Adjustable between 0 to 4%
- pressure adjustment
- 0 to 999mm of Hg Manual
- salinity correction
- 0 to 20gm/1 (Manual)
Add Quantity
Response within 4 hoursFree to enquire
Description
MT-130 : It is Used For measuring the pH , Temp. , D.O , TDS , Salinity , Turbidity , Conductivity , ORP .pHRange0 to 14pHResolution0.01pHAccuracy±0.01pH (Relative)Temp. CompAutomatic With Temp. ProbeBufferManual By KeysRecognition4.00 7.00, 9.20 pH (Automatic)Slope Adjustment80% to 120%, By Default 100%CalibrationAuto/Manual 2-Point, 3-PointmV (ORP)Range0 to ±1999mVResolution1mVAccuracy±1mV CalibrationManualTemperatureRange-20.0 to +200°CResolution0.1°CAccuracy±0.2%Input TypePt 100CalibrationManualDissolved OxygenRange0 t 20ppmResolution0.1ppmTemperature Comp.Automatic with pt 100probe manual with keysPressure Adjustment0 to 999mm of Hg ManualSalinity Correction0 to 20gm/1 (Manual)CalibrationAutomaticAccuracy±2%±1digitConductivityRange0 to 1000m mho in 6-rangesRange SelectionAutomatic 6 Ranges 0µ mho to 1000m mhoResolution0.1µ mhoCell ConstantAdjustableTemperature co.-effAdjustable between 0 to 4%Temperature Comp.Automatic for entire rangeAccuracy±0.5% of range + 1digitTurbidityRange0-100JTUResolution1JTUAccuracy±3% FS ±1digitSample Size30mm glass tubeLight6.8V Tungsten LampTDSRange0 to 200 ppt in 5 RangesRange SelectionAutomaticResolution0.1 ppmTDS Factor0.5 and adjustable manuallSALINITYRange0 to 50 pptResolution0.1 pptAccuracy±0.5% of range + 1digitTemperature Comp.AutomaticSalinity Factor0.75 and Adjustable ManuallyFEATURESDisplay16 Character * 2 lines Alphanumeric lcd.Display FormatTemp pH or temp ORP Simultaneously auto Display of Selected BufferSettingBy soft Touch KeysStorage1000 samples With Date and TimeInterfaceRS-232 Centronics ComputerReal Time Display24 hour Mode With DateError IndicationpH error , Buffer Error , ORP ErrorDigital OutputSERIAL RS-232PARALLEL CENTRONICSPrint FormatALL DATADATE WSIEAccessories1) pH Electrode2) Standard Solution 7.0 pH 4.0 pH3) ORP Electrode (On Demand)4) Temeprature Probe5) Conductivity/TDS/Salinity Cell6) DO Probe7) Instruction Manual
Verify supplier credentials before transacting. Enquiries create leads for the supplier.